Rockwell Automation 2071-APx Kinetix 3 Drive Systems Design Guide User Manual
Page 13

Rockwell Automation Publication GMC-RM005B-EN-P - September 2013
13
Kinetix 3 Drive Systems
Kinetix 3 (200V-class) Drives/TLY-A
xxxT-H (incremental) Motor Curves (continued)
Kinetix 3 (200V-class) Drives/TLY-A
xxxx-x Motor Curves
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2071-AP4 and TLY-A230T-H
4.00
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0
35.4
31.0
26.5
22.1
17.7
13.3
8.85
4.42
0
0
3000
5000
4000
1000 2000
6000
Intermittent curve represents
single-phase input.
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2071-AP4 and TLY-A230T-H (Brake)
4.00
3.50
3.00
2.50
2.00
1.50
1.00
0.50
0
35.4
31.0
26.5
22.1
17.7
13.3
8.85
4.42
0
0
3000
5000
4000
1000 2000
6000
Intermittent curve represents
single-phase input.
= Intermittent operating region
= Continuous operating region
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2071-AP8 and TLY-A2540P-x
0
3000
5000
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0
4000
1000
2000
70.8
61.9
53.1
44.2
35.4
26.5
17.7
88.5
0
Intermittent curve represents
three-phase and single-phase inputs.
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2071-AP8 and TLY-A2540P-x (Brake)
0
3000
5000
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0
4000
1000
2000
70.8
61.9
53.1
44.2
35.4
26.5
17.7
88.5
0
Intermittent curve represents
three-phase and single-phase inputs.
Torque
(N•m)
Torque
(lb•in)
2071-A10 and TLY-A310M-
x
Speed (rpm)
0
2000
4000
3000
1000
5000
12.0
10.0
8.0
6.0
4.0
2.0
0
106
88.5
70.8
53.1
35.4
17.7
0
Intermittent curve represents
three-phase input.
Torque
(N•m)
Torque
(lb•in)
2071-A10 and TLY-A310M-
x (Brake)
Speed (rpm)
0
2000
4000
3000
1000
5000
12.0
10.0
8.0
6.0
4.0
2.0
0
106
88.5
70.8
53.1
35.4
17.7
0
Intermittent curve represents
three-phase input.
= Intermittent operating region
= Continuous operating region