Rockwell Automation Liqui-Flo 20-HIM-A6 with 2.0 AC Drive User Manual

Page 5

background image

Rockwell Automation Publication LIQFLO-UM011B-EN-P - November 2012

5

Using the 20-HIM-A6 HIM with the LiquiFlo 2.0 AC Drive

Scroll Left

Scrolls left through display lines.

Scroll Right

Scrolls right through display lines.

ACK

Acknowledge

Acknowledges the fault or alarm on the pop-up screen, stops the backlight from flashing, and keeps the
pop-up screen active.

ALL

All

Clears all faults, alarms or events when a pop-up box appears from a queue screen.
Restores all Host or Port device parameters to factory defaults.

CLR

Clear

Deletes an entire text string.
Displays the Select Action pop-up box used to clear the selected fault, alarm or event, or the entire

fault, alarm or event queue.

DEL

Delete

Deletes a highlighted character.

EDIT

Edit

Accesses a displayed parameter to edit.
Accesses the Edit Process Display screen.

END

End

Displays the end (least recent) fault, alarm or event in a queue
Scrolls to the end line of data on the Device Version information screen.

ENTER

Enter

Displays the next level of a selected menu item.
Enters new values.
Performs the intended action.

ESC

Escape

Cancels port verification conflict pop-up box during procedure to resolve a conflict.
Cancels the existing screen and returns to the previous screen.
Cancels an entry.
Cancels pop-up Fault Display screen.
Displays the time zone groups list screen (only when the Date/Time Set Edit Mode screen is shown).

EXP

Exponent

Allows data entry using scientific notation for 32-bit REAL (floating point) values.

FIX

Fix

Fixes “Changed” or “Requires Configuration” port verification conflicts upon power up.

INFO

Information

Shows additional information about a selected port verification conflict upon power up.
Shows additional information about Set Default actions.

INS

Insert

Inserts a space to the left of a highlighted character.

LINK

Link

Displays a Link Edit pop-up box to link parameters.

LOWER

Lower

Displays the lower 16 bits (bits 0…15) of a 32-bit Bit-type parameter.

MOST

Most

Restores most Host or Port device parameters to factory defaults.

PAR#

Parameter Number

Navigates directly to a parameter.

PGDN

Page Down

Scrolls down to the next page of data lines on the Device Version information screen.

PGUP

Page Up

Scrolls up to the previous page of data lines on the Device Version information screen.

REF

Reference

Enters the speed reference for the Host Drive.

RESET

Reset

Resets the Process screen’s displayed process variables to the factory default process variables shown on

page 12

.

TEXT

Text

Edits user-definable text for the device selected.

TOP

Top

Displays the top (most recent) fault, alarm or event in a queue.
Scrolls to the top line of data on the Device Version information screen.

UPPER

Upper

Displays the upper 16 bits (bits 16…31) of a 32-bit Bit-type parameter.

VIEW

View

Toggles between select screens and views.
Displays the time stamp screen from a fault, alarm or event queue screen.

ZONES

Zones

Displays the Select Time Zone screen.

Label

Name

Function