3-26 Install a ControlNet Ex Media System

1. Connect one end of the trunk cable section to one of the tap

BNC connectors.

2. Slide the intrinsically-safe blue insulator over the BNC connector

to cover any exposed metal.

3. Install a 75

terminator onto the tap’s other BNC connector.

ATTENTION

Be certain that the intrinsically-safe insulator covers
all metal parts.

20078

Repeat steps 1 and 2 at the other end of
the segment.