beautypg.com

Rockwell Automation 1797-ACNR15 ControlNet Ex Redundant Media Adapter User Manual

Page 29

background image

ControlNet Ex Redundant Media Adapter 29

Publication

1797-5.14 - March 2010

Output (Intrinsically Safe)

(16 Position Male/female

Flexbus

Connector)

U

o

< 5.4V dc

I

o

< 400 mA

P

o

< 2.16 W

L

o

< 10

μ

H

C

o

< 65

μ

F

Isolation Path

Flexbus to Power Supply

Flexbus to ControlNet

ControlNet Ex Node to Other

Node

ControlNet Ex to Power Supply


Galvanic to DIN EN 60079-11

Galvanic functional

Galvanic functional


Galvanic to DIN EN 60079-11

Power Supply

(+V, -V Intrinsically Safe)

U

i

< 9.5V dc

I

i

< 1 A

P

i

< 9.5 W

L

i

= Negligible

C

i

< 120 nF

Power Consumption

8.5 W

Power Dissipation

8.5 W

Thermal Dissipation

29 BTU/hr

Conductor Wire Size

4 mm

2

(12 gauge) stranded max

1.2 mm (3/64 in.) insulation max

Weight

Approximately 200 g

Environmental Conditions

Operational Temperature

-20…70 °C (-4…158 °F)

Storage Temperature

-40…85 °C (-40…185 °F)

Relative Humidity

5…95% noncondensing

Shock

Operating

Tested 15 g peak acceleration, 11 (±1) ms pulse width

Nonoperating

Tested 15 g peak acceleration, 11 (±1) ms pulse width

Vibration

Tested 2 g @ 10…500 Hz per IEC 68-2-6

Agency Certification

CENELEC

II 2G Ex ib IIC T4

UL, C-UL

Class I, Groups A, B, C and D;

Class II, Groups E, F and G;

Class III Hazardous Locations

Class I, Zone 1, AEx ib IIC T4.

FM

Intrinsically safe Class I, Div 1, Groups A, B, C, D, T4

Associated Apparatus with Intrinsically safe

connections Class I, II, III, Div 1, Groups A--G

Intrinsically safe Class I, Zone 1, AEx ib IIC T4

INMETRO

BR-Ex ib IIB/IIC T4

IECEx

Ex ib IIC T4