Rockwell Automation 2755-G6-D Scanner with RS-232 Option User Manual
Page 32

Setup Instructions
Chapter 4
4–8
Table 4.A (continued)
Scanner Default Settings
Serial Communication
Parameters
Options
Default
Baud Rate
300, 600, 1200, 2400, 4800, 9600,
19200
9600
Serial Data
Transmission
(Start Bit, Data Bits,
Stop Bits, Parity)
7 Data Bits/1Stop Bit/ Odd Parity
Even Parity
Mark Parity
Space Parity
7 Data Bits/2 Stop Bit/Odd Parity
Even Parity
Mark Parity
Space Parity
8 Data Bits/1Stop Bit/ Odd Parity
Even Parity
Mark Parity
Space Parity
No Parity
8 Data Bits/2Stop Bit/ No Parity
7 Data Bits/1Stop Bit/
Space Parity
Intercharacter Delay
User Defined Delay (in msec) or
No Intercharacter Delay
No Intercharacter Delay
Protocol
XON/XOFF, CTS, RTS or None
None
Serial Transmit Buffer
Full Buffering, No Buffering,
One Label Buffering
Full Buffering
Symbologies
Code
Options
Default
Code 39
Disable Code 39
Enable Standard Code 39
Enable Full ASCII Code 39
Enable Standard Code 39
Enable or Disable Modulo 43
Check Character
Disable
Enable or Disable Transmission
of Start/Stop Characters
Disable
Minimum Label Length
1
Maximum Label Length
32