Installation chapter 3 – Rockwell Automation 1770-KF2 Data Highway or Highway Plus Interface Module User Manual User Manual
Page 26

Installation
Chapter 3
3-2
Figure 3.1
Communication Option Switches
O
O 1 2 3 4 5
O
O 1
2
3
13529
O
O 1
2
O
O 1
2
3
O
O 1
2
O
O 1 2 3 4
N
F
F
N
F
F
N
F
F
N
F
F
N
F
F
N
F
F
Station Number
(SW-2, SW-3, SW-4)
Asynchronous Link
Features (SW-1)
Network Link
Communication
Asynchronous Link
Communication
O
O 1
2
N
F
F
ON
OFF
ON
OFF
ON
OFF
Front View
Side View
Й
Й
Й
O
O 1
2
N
F
F
O
O 1
2
N
F
F
RS-232-C/RS-422-A
Selection (SW-8)
Network Link
Selection
(SW-7)
Rate (SW-6)
Rate (SW-5)
Important: The KF2 reads the status of the communication option
switches only at power-up, so you must make your selection with the
KF2’s power off.
Asynchronous Link Features
The following table shows you how to set the asynchronous link features
using Switch Numbers 1, 2, and 5.
If You Want
to Select
With Error
With
With
Embedded
SW-1
Protocol as:
Check as:
Parity as:
Responses:
1
2
3
4
5
Full Duplex
BCC
None
No
OFF
OFF
N/A
N/A
OFF
Full Duplex
BCC
Even
No
ON
OFF
OFF
Full Duplex
BCC
None
Yes
OFF
ON
OFF
Full Duplex
BCC
Even
Yes
ON
ON
OFF
Half Duplex
BCC
None
No
OFF
OFF
ON
Half Duplex
BCC
Even
No
ON
OFF
ON
Full Duplex
CRC
None
Yes
OFF
ON
ON
Half Duplex
CRC
None
No
ON
ON
ON
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (2 pages)
- 100 Contactors with DC Coil (1 page)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)