Rockwell Automation 1770-KF2 Data Highway or Highway Plus Interface Module User Manual User Manual
Page 196
![background image](/manuals/579289/196/background.png)
Error Reporting
Chapter 7
7Ć41
Here is a list of relevant PLC-3 status codes for the STS byte and the
EXT STS byte.
Bits
Hex Value
Meaning
STS Byte
04Ć07
0
Success, no error.
1
Illegal command or format.
2
Host has a problem and will not communicate.
3
Remote station host is not there, disconnected, or shut down.
4
Host could not complete function due to hardware fault.
5
Addressing problems or memory protect rungs.
6
Function disallowed due to command protection selection.
7
Processor is in Program mode.
8
Compatibility mode file missing or communication zone
problem.
9
Remote station cannot buffer command.
A
Not used.
B
Remote station problem, due to download.
C
Not used.
D
Not used.
E
Not used.
F
Indicates that there is an error encoded in the EXT STS byte.
EXT STS Byte
0
Not used.
1
Error in converting block address.
2
Fewer levels specified in address than minimum for any
address.
3
More levels specified in address than system supports.
4
Symbol not found.
5
Symbol is of improper format.
6
Address doesn't point to something usable.
7
File is wrong size.
8
Cannot complete request, situation changed since start of
command.
9
File is too large.
A
Transaction size plus word address are too large.
B
Access denied, improper privilege.
C
Condition cannot be generated.
D
Condition already exists.
E
Shutdown could not be executed.
F
Requestor does not have upload or download access.
10
Histogram overflow.
11
Illegal data type.
12
Bad parameter.
13
Address reference exists to deleted data table.
14
ĆFF not used.