Rockwell Automation 1770-KF2 Data Highway or Highway Plus Interface Module User Manual User Manual
Page 173
Error Reporting
Chapter 7
7Ć18
Code (If Applies)
EXT STS STS
Meaning
Error
Code
8
F0
238
The file size decreased between packets of a multiĆpacket
transaction and became too small for the total transaction.
9
F0
239
File is larger than 65,535 words.
A
F0
240
Sum of total transaction size and PLCĆ3 address is greater than
65,535 bytes.
PLCĆ3 BIT WRITE COMMANDS
10
81
More than 4 bytes of data exist after the PLCĆ3 address in the
command message.
30
83
The local 1775ĆKA module has executed a shutdown request.
40
84
Backplane error (memory parity or timeout/disconnect).
60
86
Keyswitch setting disallows access to file.
70
87
Local PLCĆ3 in Program mode.
1
F0
231
Error in converting the block address
(major section > 63, context > 15, section > 15).
2
F0
232
Three or fewer addressing levels specified for a PLCĆ3 word
address.
3
F0
233
Conversion of a file address to a block address resulted in more
than 9 addressing levels.
4
F0
234
Symbolic address not found.
5
F0
235
Symbolic address is of length zero or more than 8 bytes.
6
F0
236
1. File not found.
2. Destination address does not specify a PLCĆ3 word.
3. The PLCĆ3 address specifies more levels than required.
4. Word specified by the PLCĆ3 address does not exist.
9
F0
239
File is larger than 65,535 words.
B
F0
241
Remote station does not have access to the destination file.
Remote Error Codes
Remote error codes are those reported in a reply message from a remote
station that received a command message from the local PLC-3 station.
These error codes are stored under user symbol ERROR in the local
PLC-3 station.