beautypg.com

Rockwell Automation 1329I Integrated AC Drive/Motor, Series B FRN 3.X User Manual

Page 66

background image

A-2

Technical Specifications

1329I-5.5 Integrated Drive/Motor — January, 2000

Maximum continuous output current:

Maximum output current:

Important:

Maximum current ratings above are for the CT rating. When VT is
selected, the maximum output current will be limited to 110%.

Output frequency:

• 0 to 120 Hz

Carrier frequency:

• 8 kHz

Input Voltage

Unit HP

Output Current

(Motor Rated Amps)

460 VAC

1 HP

1.7 A

460 VAC

2 HP

3.2A

460 VAC

3 HP

4.5 A

460 VAC

5 HP

6.9 A

230 VAC

1 HP

3.4 A

230 VAC

2 HP

6.4 A

230 VAC, 1-phase

1 HP

3.4 A

230 VAC, 1-phase

2 HP

6.4 A

115 VAC

1 HP

6.8 A

Input Voltage

Unit HP

Maximum Output Current

(150% Rated Amps)

460 VAC

1 HP

2.55 A

460 VAC

2 HP

4.8 A

460 VAC

3 HP

6.75 A

460 VAC

5 HP

10.35 A

230 VAC

1 HP

5.1 A

230 VAC

2 HP

9.6 A

230 VAC, 1-phase

1 HP

5.1 A

230 VAC, 1-phase

2 HP

9.6 A

115 VAC

1 HP

10.2 A