Series b summary of changes, Series b application/installation considerations – Rockwell Automation 1329I Integrated AC Drive/Motor, Series B FRN 3.X User Manual
Page 3

1329I-5.5 Integrated Drive/Motor — January, 2000
Series B Summary of Changes
• Additional Start Mode Selection Feature
Local operator units can now be controlled from either the operator controls or the
terminal block.
• Terminal Block Stop Input
The terminal block stop input and local operator stop key are now active for all start
mode selections.
• Zero Speed Operation
The minimum speed has been reduced from 90 RPM (3 Hz) to zero.
• Storage Temperature Range Extended
The storage temperature rating has been extended from 70°C to 85°C.
• CE Mark
The unit now conforms to the EMC and LVD directives for CE. An optional line
filter is required.
• CE Line Filter Option
Single and three phase line filters are now available. This option can be mounted
internally or is packaged for external mounting.
• DeviceNet Communication Option
A DeviceNet communication option is now available, which is installed inside the
unit. Refer to the
Bulletin 1329I DeviceNet Option User Manual
for more
information.
• Drive Parameters Added
The unit now has drive display parameters and drive program parameters. These
parameters can be viewed or changed through a DeviceNet connection. Refer to the
Bulletin 1329I DeviceNet Option User Manual
for more information.
Series B Application/Installation Considerations
Keep the following in mind if you are replacing a Bulletin 1329I Series A with a Series
B unit.
Minimum Speed
• The minimum speed has been reduced from 90 RPM (3 Hz) to 0 RPM (0 Hz).
Terminal Block Stop Input
• Terminal block stop input must be present for local operator control units.