Rockwell Automation 1329I Integrated AC Drive/Motor, Series B FRN 3.X User Manual
Page 13
Step 1 - Identify Your Unit
1-5
1329I-5.5 Integrated Drive/Motor — January, 2000
1.2.4 Operating the Unit Using the Local Operator Controls
➊
These functions are only active when in local operator start mode (see Section 8.3.9).
➋
If the unit is using a terminal block or preset speed reference (see Section 8.3.2), pressing
the
or
key will have no effect on unit operation.
Important:
If the local operator controls are disconnected from or connected to the
unit after power up, the unit will stop due to a non-resettable fault. Refer
to Chapter 11 for information about faults.
Desired Action
User Steps
Start the unit.
➊
Press the green
key.
Stop the unit.
Press the red
key.
Change the direction of motor rotation.
➊
Press the
key.
Clear faults or abort Auto Restart
sequence.
Press the
key.
Decrease the speed reference.
➋
Press the
key until the speed reference
displayed is the desired value. The longer the
key is held down, the faster the value decreases.
Display the current speed reference.
➋
Press the
or
key once.
The display returns to indicating speed in RPM or
percent load after three to five seconds. Holding
down either key will change the speed reference.
Display the speed in RPM
No action required; speed in RPM is the default
display based on status of terminal 12 (see
Section 7.4). If the
or
keys are not
pressed for several seconds, the display returns
to indicating actual motor speed in RPM.
Display percent load
Close contact on terminal 12 (see Section 7.4)
Increase the speed reference.
➋
Press the
key until the speed reference
displayed is the desired value. The longer the
key is held down, the faster the value increases.
RESET