2 mounting dimensions for nema frames, Mounting dimensions for nema frames – Rockwell Automation 1329I Integrated AC Drive/Motor, Series A User Manual
Page 18
3-2
Step 3 - Mount the Unit
1329I-5.0 Integrated Drive/Motor — January, 1999
3.2
Mounting Dimensions for NEMA Frames
Figure 3.1
NEMA Frame Mounting Dimensions
Frame Size
Dimensions in inches (mm)
A
2E
H
D
BF
AJ
AK
U
AH
S
ES
56C
6.71
(170)
5.50
(140)
0.34
(8.6)
3.50
(89)
3/8-16
5.88
(149)
4.50
(114)
0.625
(15.9)
2.06
(52)
.19 SQ
(4.8)
1.25
(32)
143TC
145TC
6.71
(170)
5.50
(140)
0.34
(8.6)
3.50
(89)
3/8-16
5.88
(149)
4.50
(114)
0.875
(22.3)
2.12
(54)
.19 SQ
(4.8)
1.25
(32)
182TC
184TC
8.50
(216)
7.50
(191)
0.34
(8.6)
4.50
(114)
1/2-13
7.25
(184)
8.50
(216)
1.125
(28.6)
2.62
(67)
.25 SQ
(6.4)
1.50
(38)
Frame Size
Dimensions in inches (mm)
BC
BB
BA
B
2F 1
2F 2
EV
C
P
BV
56C
0.19
(4.8)
0.12
(3.0)
2.75
(70)
6.50
(165)
3.00
(76)
5.00
(127)
0.47
(12)
15.90
(404)
8.38
(213)
10.14
(258)
143TC
0.12
(3.0)
0.12
(3.0)
2.75
(70)
6.50
(165)
4.00
(102)
5.00
(127)
0.47
(12)
16.46
(418)
8.38
(213)
10.14
(258)
145TC
0.12
(3.0)
0.12
(3.0)
2.75
(70)
6.50
(165)
4.00
(102)
5.00
(127)
0.47
(12)
15.96
(405)
8.38
(213)
10.64
(270)
182TC
0.12
(3.0)
0.25
(6.4)
3.50
(89)
6.50
(165)
4.50
(114)
5.50
(140)
0.50
(13)
18.75
(476)
8.80
(224)
12.39
(315)
184TC
0.12
(3.0)
0.25
(6.4)
3.50
(89)
6.50
(165)
4.50
(114)
5.50
(140)
0.50
(13)
19.75
(502)
8.80
(224)
13.39
(340)
45
D
2E
A
P
AJ
BF
H - Diameter Through
Face Runout and Eccentricity .004 Max. T.I.R.
Shaft Runout .002 Max. T.I.R.
S - Key Width/Height
ES - Key Length
3/4 Conduit
Both Sides
* Denotes Control Wiring Ports
** Denotes Input Power Port Opposite Side
B
C
BB
BV
6.00
AK
BA
2F 1
2F 2
EV
4.50
BC
AH
U
**
.75
8.01
*