Torque specifications, Scr module access, Scr module access” on – Rockwell Automation 1336S, 1336F, 1336E, 1336T, 1336-SN-SP18A Snubber Board Kit User Manual
Page 11
![background image](/manuals/578222/11/background.png)
1336-5.39 – August, 1999
I-11
Torque Specifications
The following table lists fastener locations by component,
application, and torque specifications. Refer to “Torque Sequence” on
page I-4 for fastening two-point, four-point, and six-point
components to the heat sink.
SCR Module Access
Important: Before you remove connections and wires from the drive
components, mark the connections and wires to correspond with their
component connections and terminals to prevent incorrect wiring
during assembly.
Component
Fastener Application
Fastener Used
Torque
in.-lb
Torque
N-m
SCR Module
Module to Heat Sink
M6 x 16 mm Screw
52
5.9
Snubber Board
Board to SCR
M4 x 8 mm Screw
12 – 16
1.4 – 1.8
Gate Driver Board Mounting Plate
Plate to Chassis
M5 x 10 mm Screw
23 – 36
2.6 – 4.1
Control Board Mounting Plate
Plate to Gate Driver Board Mounting Plate
M6 Nut
23 – 36
2.6 – 4.1
Control Board Mounting Plate
Plate to Gate Driver Board Mounting Plate
M4 x 8 mm Screw
12 – 16
1.4 – 1.8
Enclosure Bottom, Top, and Side Panels
Enclosure Sheet Metal
M5 x 10 mm Screw
23 – 36
2.6 – 4.1
TB1 Wires
Wires to TB1
M8 Nut
52
5.9
Converter Bus Bar Wires
Wires to Converter Bus Bar
M6 x 12 mm Screw
50 – 72
5.6 – 8.1
Ground Wire TE (Gate Driver Board)
Wire to TB1 Terminal TE
Compression
6 – 8
0.7 – 0.9
TB20 Wires, PLC Comm Adapter Board
Wires to TB20
Captive Screw
–
–
TB21 Wires, PLC Comm Adapter Board
Wires to TB21 on Main Control Board
Captive Screw
–
–
TB5 Wires, Standard Adapter Board
Wires to TB5 on Main Control Board
Captive Screw
12 – 16
1.4 – 1.8
TB6 Wires, Standard Adapter Board
Wires to TB6 on Main Control Board
Captive Screw
12 – 16
1.4 – 1.8
TB7 Wires, Standard Adapter Board
Wires to TB7 on Main Control Board
Captive Screw
12 – 16
1.4 – 1.8
TB3 Wires, Standard Adapter or
L-Option Board
Wires to TB3 on Control Interface Board or
L-Option Board
Captive Screw
8 – 10
0.9 – 1.1
Enclosure Door Ground Wire
Wire to Enclosure Door
M6 Nut
23 – 36
2.6 – 4.1
!
ATTENTION: Disconnect and lock out power from
the drive before disassembling the drive. Failure to
disconnect power may result in death or serious injury.
Verify bus voltage by measuring the voltage between
+DC and -DC on Terminal Block TB1. Do not attempt
to service the drive until the bus voltage has discharged
to zero volts.
ATTENTION: Wear a wrist-type grounding strap
when servicing drives. Failure to protect drive
components against ESD may damage drive
components. Refer to “Electrostatic Discharge
Precautions” on page I-4.