Output image table and tags, Output channel tags – Rockwell Automation 56RF RFID System User Manual User Manual
Page 62
62
Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Chapter 7
RSLogix 5000 Controller Tags
• Reset
– The channel reset bit will indicate the reset status of the RFID
channel. A value of 0 indicates the channel is not in reset, a value of 1
indicates the channel has completed a reset.
• ResetInProgress
– The channel ResetInProg bit will indicate the status of
an RFID channel reset. A value of 0 indicates that the RFID channel is not
currently undergoing a reset; a value of 1 indicates a reset in progress on
that channel.
• TagPresent
– The channel TagPresent bit will indicate the status of a tag
at the RFID channel. A value of 0 indicates there is not tag present at the
transceiver; a value of 1 indicates one or more tags have been detected at
the transceiver.
Output Image Table and Tags
Expand the RFID_1:O by clicking the “+” box. The shows the output image
table, which has the following tags:
• Channel
– See Output Channel Tags.
• Pt00Data
– The Pt00Data bit is used to turn output point 0 either on or
off. A value of 0 will be used to turn the output point off, a value of 1 will
be used to turn the output point on.
• Run
– The Run bit is used to place the RFID block into run or program
mode. A value of 0 will be used for program mode, a value of 1 will be used
for run mode. When in program mode, the interface will maintain the
connection to the processor but will not execute commands. The discrete
output point will follow the mode of the processor as well as the Run bit,
with the Run bit overriding.
Output Channel Tags
Expand the RFID_1:Channel by clicking the “+” box. This shows that two
channels exist: Channel[0] and Channel[1]. Expand the RFID_1:Channel[0] by
clicking the “+” box. Each channel has the following tags: