Error Codes
The error codes for the RFID interface block are stored in the input for each
channel. In the examples in the manual, the error codes are stored in the image
table RFID_1:I:Channel[0].ChError and RFID_1:I:Channel[1].ChError.
• OK (Decimal 0) – Indicates there are no issues with the channel in
question when the decimal value of these bits is equal to zero.
• Transceiver not found (Decimal 1) – Indicates that communications
with the transceiver for the specified channel has been lost.
• Invalid Response (Decimal 2)– Indicates that the response to a command
is not what was expected.
• Invalid Parameter (Decimal 3) – Indicates that either a parameter passed
or received was out of bounds.
• No Tag Detected (Decimal 4)– Indicates that a command was attempted
on a channel but there was no tag detected in the field.
• Instruction Timed Out (Decimal 5)- Indicates that the timeout value
associated with a command was exceeded before a response could be
obtained.
• Block Access Error (Decimal 6) – Indicates that either:
– A read command attempted to read a block but was denied access.
– A write command attempted to write to a block but was denied access.
• Format Error (Decimal 7)– Indicates that the format of the command or
response was invalid.
Error Codes
Status Word
Binary
0
OK
0000
1
Transceiver not found
0001
2
Invalid Response
0010
3
Invalid Parameter
0011
4
No Tag Detected
0100
5
Instruction Timed Out
0101
6
Block Access Error
0110
7
Format Error
0111
8
Tag Communications Error
1000
9
Address Error
1001
10
Mismatch Error
1010
11
Internal Channel Error
1011
12
Malformed Packet
1100
13
Unit in Program Mode
1101
14
Reserved
1110
15
Module Error
1111