beautypg.com

Transceiver connection, Digital input connection, Digital output connection – Rockwell Automation 56RF RFID System User Manual User Manual

Page 32

background image

32

Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011

Chapter 3

Electrical Installation

Transceiver Connection

The M12 QD female connector for the transceivers is shown below. Pin 5 is the
cable shield connection and is connected only at the block to functional earth
(FE).

Digital Input Connection

The female M12 QD input connector is shown below.

Digital Output Connection

The female M12 QD output connector is shown below.

Pin

Function

1

24V DC power

2

Data +

3

24V common

4

Data -

5

Shield/FE

Pin

Function

1

24V DC power

2

Not used

3

24V common

4

Digital input

5

Shield/FE

Pin

Function

1

Not used

2

Not used

3

24V common

4

Digital output

5

Shield/FE

4

3

1

2

5

4

3

1

2

5

4

3

1

2

5