RSLogix 5000 Controller Tags
Chapter 7
Table 17 - Allowable Commands
• ContReadMode
– The channel ContReadMode bit will indicate the
status of Continuous Read Mode for an RFID channel. A value of 0
indicates that the RFID channel is not in continuous read mode; a value of
1 indicates that the RFID channel is in continuous read mode. While in
Continuous Read Mode, the interface will ignore all other commands
except a Stop Continuous Read.
• Counter
– The channel counter word is a 2-byte value that will increment
its value by 1 after the interface has completed execution of a command.
This value will roll over to 0 after it counts to 65535 and start again; at
power up this value must be 0.
• Data
– Depending on the Data Format, the channel Data word is an array
of either 2-byte values or an array of 1-byte values that total 160 bytes in
length. This array is used to store information returned from the RFID
interface. Upon completion a command, reply data will be deposited in
this array and the length of the reply (in 16-bit word increments) will be
placed within the associated length field; at power up this value must be 0.
• Fault
– The channel fault bit will indicate the fault status of the RFID
channel. A value of 0 indicates the channel is operating normally, a value of
1 indicates the channel has faulted.
• Length
– The channel length word is a 2-byte value that will indicate the
data length for specific commands. Upon completion of a command, this
word will be populated with the number of 16-bit words returned to the
data field; at power up this value must be 0.
Value
Command
Description
1
Read Single Block
Reads a single block of user data.
2
Read Multiple Blocks
Reads multiple blocks of user data from a tag.
3
Multi-tag Block Read
Reads information from up to four tags.
4
Read Byte
Reads bytes of user data from a tag.
5
Start Continuous Read
Initiates continuous read mode.
6
Stop Continuous Read
Stops continuous read mode.
8
Teach Continuous Read
Provides the ability to automatically set the best time to start
reading in continuous read mode.
10
Write SingleBlock
Writes a single block of user data.
11
Write Multiple Blocks
Writes multiple blocks of user data to a FRAM tag.
12
Multi-tag Block Write
Writes multiple blocks of user data to up to four tags.
13
Clear Multiple Bytes
Clears multiple bytes of user data in a tag.
14
Write Byte
Writes bytes of data to a tag.
20
Inventory
Counts the number of blocks in the field (up to four) and returns
the UUID of the first tag in the field.
31
Read Transceiver Settings
Read Baud Rate, Device ID,Retry Time, and Gain.
33
Get Version Information
Retrieves the firmware version from the transceiver.
34
Get System Information
Gets Info Flags,UUID, DSFID, AFI,Memory Size, and IC Reference
from Tag.
40
Lock Block
Locks blocks of memory.
41
Write AFI
Write the AFI byte to the tag.
42
Lock AFI
Locks the AFI byte from future changes.
43
Write DSFID
Writes the DSFID byte to the tag.
44
Lock DSFID
Locks the DSFID byte from future changes.
45
Get Multiple Block Security Status
Retrieves that security status of multiple blocks within a tag.