Burnham SCG 1100-H4 User Manual
Page 66
H.
Operating Instructions.
1. Follow Operating Instructions to place boiler in
operation. See Figure 36.
2. Electronic Ignition Modules with LED indicators.
Table 10 cross-references the ignition module
terminal designations to the ignition terminal
Figure 7: lED locations
Ignition Module
Terminal Designation
Wiring Ladder Diagram
Terminal Number
MV
1
MV/PV
2
PV
3
GND
4
24V (GND)
5
24V
6
SPARK
9
TABlE 10: IGNITION MODUlE TERMINAl
CROSS-REFERENCE
Yellow LED
Flash Code
a
Indicates
Recommended Service Action
Heartbeat
Normal Flame Signal
N/A
2
Weak Flame Signal -
System will operate reliably but flame signal is
less than desired.
Note: This indication may flash temporarily
during or shortly after lightoff on some appli-
cations.
Perform routine maintenance to
assure optimum flame signal.
1
Marginal Flame Signal (less than 1.1 µA) -
System may not operate reliably over time.
Service call recommended.
Note: This indication may flash temporarily
during or shortly after lightoff on some appli-
cations.
Check gas supply, pilot burner, flame
sense wiring, contamination of flame
rod, burner ground connection.
OFF
No Flame or Flame Signal -
below minimum threshold for system
operation.
N/A
a
Flash Code Descriptions
- Heartbeat: Constant ½ second bright, ½ second dim cycles.
- The flash code number signifies that the LED flashes X times at 2Hz, remains off for two
seconds, and then repeats sequence.
numbers in the wiring ladder diagrams. The yellow
LED indicates the status of the flame, see Table 11.
The green LED indicates the status of the system,
see Table 12. See Figure 37 for LED locations. See
Figure 38 for Troubleshooting Guide.
TABlE 11: yEllOW lED FlAME CODES