Maintenance intervals – MTS TestLine User Manual
Page 120

Annually
Biweekly
Weekly
Daily
Calendar Time using 8 hour Running
Time rate per day
2,000
1,500
1000
500
80
40
8
Running Time-Hours
MTS
MTS
MTS
MTS
Check response to full stroke waveform,
visual and audible.
MTS
MTS
MTS
MTS
Check displacement control valve balance.
MTS
MTS
MTS
MTS
Check valve dither response.
Maintenance Intervals
The following table lists the recommended interval for each of these procedures.
Load Unit Maintenance Intervals
When to Do It
What to Do
Before the start of each day’s testing.
Make daily inspections.
Depends on the operating environment; more often
in humid environments.
Take rust prevention precautions.
At least once a month.
Perform label inspection.
After actuator or force transducer installation; when
a better alignment between the two is desired.
Align the force transducer.
At least once a month; more often as required by
operating conditions.
Check the accumulators’ precharge pressures.
Adjust if necessary.
Weekly; more often as required by operating
conditions.
Clean exposed actuator piston rod.
When the indicator is in bypass position or when
hydraulic fluid is changed.
Change HSM filter.
When servovalve performance has deteriorated.
Perform Model 252 Servovalve maintenance:
change filter.
120 | MTS TestLine Test System Operation
Maintenance