3 file header for application data, L-force loader – Lenze Loader L-force Loader User Manual
Page 43

L
DMS 4.0 EN - 07/2007
43
L-force Loader
Appendix
File header for application data
7.3
File header for application data
For the interpretation of the header information applies: least-significant byte first:
Note!
The file header is not valid for *.lc7 files. *.lc7 files can only be transferred to the
"9300 servo cam profiler" target system.
Name
Data type
Data length
in bytes
Contents
wSizeHeader
WORD
2
Length of the header in bytes
wDataType
WORD
2
Specification identifier of the data
• After the download this information is available under
C2131.
0 ... 10000 Lenze-specific data
> 10000 User data
dwVersion
DWORD
4
Data version
• After the download this information is available under
C2132.
dwRealSize
DWORD
4
Length of the user data in bytes (without header)
dwTimeStamp
DWORD
4
Time stamp of the last data change
• After the download this information is available under
C2133.
wLicenseInfo
WORD
2
Reserved for future extensions
wSizeSymbolicName
WORD
2
Length of the symbolic file name
achSymbolicName
ACH
wSize
Symbolic
Name
Character array containing the symbolic file name
• After the download this information is available under
C2130.
wCopyToRam
WORD
2
Selection whether the data is automatically copied to the
application RAM of the PLC after the download, or not.
• Maximum data length = 128 kbytes (RAM blocks 1 & 2)
0 Data is not copied to the application RAM.
1 Data is copied to the application RAM.
2 ... 65535 Reserved
dwReserved
DWORD
4
Reserved for future extensions
awSizeAddInfo
DWORD
190
E4 00 0A 00 01 00 00 00
1C FF 00 00
wSizeHeader = 00 E4
= 228 Byte
hex
wDataType = 00 0A
= 10 (Cam data)
hex
dwVersion = 00 00 00 01
hex
dwRealSize = 00 00 FF 1C
= 65308 Byte
hex