L-force loader – Lenze Loader L-force Loader User Manual
Page 30
L-force Loader
Control via script files
Structure of the script file
30
DMS 4.0 EN - 07/2007
L
O
Tip!
The script is not tested for correctness before it is being processed, i.e. script
processing does not stop before an error occurs. The error can be analysed and
eliminated using the log file.
Communication settings - [COMMUNICATION] section
General settings - [COMMON] section
Key
Parameter
Baudrate
Baud rate of the system bus in kBaud.
• The baud rate selection in the script is optional.
• If the baud rate is not defined in the script, the value set in the system bus
configurator will be used.
Key
Parameter
NumberOfDevices
Number of the target systems to be programmed (max. 63).
ShowProcessing
Status window display:
0 = Status window not displayed (standard setting).
1 = Status window displayed.
MaxNumberOfErrors
The latest version no longer supports this entry and ignores it, if necessary (e.g. in older
script files).
ExitAfterDownload
Automatic stop of »L-force Loader« after the script has been processed:
0 = »L-force Loader« does not stop after processing is completed (standard setting).
1 = »L-force Loader« stops after processing is completed.