Lenze Loader L-force Loader User Manual
Page 16
![background image](/manuals/566325/16/background.png)
L-force Loader
Operation
How to configure the communication settings
16
DMS 4.0 EN - 07/2007
L
5.1.1
Example: Configuring a point-to-point connection via LECOM
M
How to configure a point-to-point connection via LECOM:
1. Select ProgramsLenzeL-force Loader - 4.0L-force Loader from the Start menu
to start the »L-force Loader«.
In the »L-force Loader«:
2. Select OptionsDriveServer configurator to open the »DriveServer configurator«.
In the »DriveServer configurator«:
3. Select FileConnect to build up a connection to the selected DriveServer.
• Wait until the Please wait dialog disappears and the connection to the
DriveServer has been built up.
4. Select ConfigurationBus server to open the Bus server configuration dialog box.
• The right list field lists all bus servers which have been assigned to the
DriveServer.
• To remove an assignment, select the corresponding bus server from the right
list field and click the Delete button.
5. Click Refresh to list all bus servers available on the selected PC in the left list field.
6. For LECOM, select "Lenze OPC LECOM server" from the left list field and click Add to
assign this bus server to the DriveServer.
• If necessary, repeat the above steps to assign further bus servers to the Drive
Server.
7. Click OK to accept the settings and close the Bus server configuration dialog box.
• The bus servers assigned to the DriveServer will be listed in the name area under
the "Online" element.
8. Select FileDisconnect to end the connection to the selected DriveServer.
9. Select FileExit to exit the »DriveServer configurator«.
Note!
The configuration described below only has to be carried out once.