L-force loader – Lenze Loader L-force Loader User Manual
Page 38

L-force Loader
Appendix
Error numbers, causes & remedies
38
DMS 4.0 EN - 07/2007
L
C602h
Error while identifying the FIF.
(Product code cannot be read.)
Check the communication parameters.
If the problem still occurs, contact the Lenze
Hotline.
C603h
Error while identifying the FIF.
(ID cannot be read.)
C604h
Error while copying the application data.
Check the name of the target system causing
the error (e.g. "DEVICE001") in the log file and
the specifications in the script file.
C605h
Application data of file and target system is
identical.
Only status message, no remedy required.
C606h
Application data cannot be transferred.
Repeat the download.
If the problem still occurs, contact the Lenze
Hotline.
C607h
Error while opening the application data.
Check the name of the target system causing
the error (e.g. "DEVICE001") in the log file and
the specifications in the script file.
C608h
No target system selected.
Check whether a target system has been
selected.
C60Ah
Internal program error: OPC item cannot be
created.
Restart »L-force Loader«.
If necessary, restart PC.
C60Bh
Internal program error: OPC item cannot be
read.
Restart »L-force Loader«.
Check whether the target system can be
addressed.
C60Ch
Internal program error: OPC item cannot be
written.
Reinstall »L-force Loader«.
If the problem still occurs, contact Lenze.
C60Dh
Internal program error: OPC control.
Restart PC.
Reinstall »L-force Loader«.
C60Eh
Error while reading a file.
Check the path of the parameter file.
Communication and download errors
D100h
Error during the start of the "OPC Ctl"
component.
• Component has not been installed or has
not been correctly registered.
Reinstall »L-force Loader«.
D101h
No connection to the OPC server.
Check that the OPC server has been installed
correctly.
Reinstall »L-force Loader«.
D102h
OPC server is not in status "Running".
Restart PC.
D103h
Error while creating an OPC item.
Reinstall »L-force Loader«.
D104h
Error while downloading.
The error message contains causes and
information about troubleshooting.
D105h
Error while connecting to the OPC server.
Restart PC / reinstall »L-force Loader«.
D106h
Error while disconnecting from the OPC
server.
Restart PC / reinstall »L-force Loader«.
Error number
Cause
Remedy