5 how to download data, How to, Download data – Lenze Loader L-force Loader User Manual
Page 25: C 25), How to download data, L-force loader
L
DMS 4.0 EN - 07/2007
25
L-force Loader
Operation
How to download data
5.5
How to download data
As long as at least one file has been opened for the download, the Download... function will
be available in online mode. Use this function to download the selected file(s).
Download sequence
For the download, the following sequence applies:
1. DDS binary files will always be downloaded first.
2. Application data will be downloaded next.
3. GDC parameter set files will be downloaded last.
This sequence does not apply to the controllers of the "L-force 9400 Servo Drives" series
since to them only L-force 9400 applications can be downloaded.
Before downloading a file
The results of the safety checks carried out before a download are listed in a log in the
dialog area.
r
The download can only be carried out if all safety checks have been passed successfully.
r
If one of the safety checks is not passed, an error number will be displayed in the log.
r
Before the download of DDS binary files and application data, it is also checked
whether the data in the target system is newer than or identical with the data to be
downloaded. If necessary, a corresponding message will be indicated and you can
select if the download shall be continued or stopped.
r
Parameter sets can be transferred in two different ways.
During the download
The name of the file being downloaded is displayed in the status bar. The progress of the
download is indicated in form of a bar.
r
If an error occurs during the download, an error message with an error number will be
displayed.
Error numbers, causes & remedies
Note!
After selecting the Download... function, the »L-force Loader« changes from
online mode to the so-called download mode. For safety reasons, the program
cannot be closed in download mode.
Please note that the controller must be inhibited in the target system for the
download.
• For target systems with PLC functionality, the PLC program must additionally
be stopped.
• For controllers of the "L-force 9400 Servo Drives" series the application must
be stopped as well.
If these requirements are not met, a corresponding message will be indicated.