DFIN (MXI2): Track error A-/A [0x00aa0000]
DFIN (MXI2): Track error B-/B [0x00aa0001]
DFIN (MXI2): Track error Z-/Z [0x00aa0002]
DFIN (MXI2): Signal error enable/lamp control [0x00aa0003]
DFIN (MXI2): Supply cannot be corrected anymore [0x00aa0004]
DFOUT (MXI2): Maximum frequency reached [0x00aa0005]
Response (Lenze setting in bold)
Setting:
(; Adjustable response)
;
No System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause
Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of signal cable for track A.
• Check signal cable for track A.
• Check encoder.
Response (Lenze setting in bold)
Setting:
(; Adjustable response)
;
No System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause
Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of signal cable for track B.
• Check signal cable for track B.
• Check encoder.
Response (Lenze setting in bold)
Setting:
(; Adjustable response)
;
No System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause
Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of signal cable for track Z.
• Check signal cable for track Z.
• Check encoder.
Response (Lenze setting in bold)
Setting:
(; Adjustable response)
;
No System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause
Remedy
Digital frequency extension module in MXI2:
Interruption (open circuit) of signal cable for "Enable"
signal or no "Enable" signal available.
• Check signal cable for "Enable" signal.
• Check encoder.
Response (Lenze setting in bold)
Setting:
(; Adjustable response)
;
No System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause
Remedy
Digital frequency extension module in MXI2: The
encoder voltage controlled by the digital frequency input
has reached the voltage limit.
Check encoder.
Response (Lenze setting in bold)
Setting:
(; Adjustable response)
;
No System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked : Warning ; Information
Cause
Remedy
Digital frequency extension module in MXI2: Limit
frequency at the digital frequency output reached.
• The digital frequency has reached the limit value set
Check set limit value.