C14036 | actual position dfin, C14037 | actual speed dfin, C14040 | resp. to track monitoring dfin – Lenze E94AYFLF Digital frequency module User Manual
Page 41: C14041 | resp. to dfin enable sig. miss, C14040, C14041, C14036, C14037, Is executed
EDS94AYFLF EN 3.2 - 10/2010
L
41
Digital frequency extension module | Parameter setting & configuration
Parameter reference
Parameter list | C14036
C14036
C14037
C14040
C14041
Parameter | Name:
C14036 | Actual position DFIN
Data type: INTEGER_32
Index: 10539
d
= 292B
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
;
Read access Write access CINH PLC-STOP No transfer
Scaling factor: 10000
Parameter | Name:
C14037 | Actual speed DFIN
Data type: INTEGER_32
Index: 10538
d
= 292A
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit/s
214748.3647
;
Read access Write access CINH PLC-STOP No transfer
Scaling factor: 10000
Parameter | Name:
C14040 | Resp. to track monitoring DFIN
Data type: UNSIGNED_8
Index: 10535
d
= 2927
h
Digital frequency extension module in module receptacle MXI2:
Response when track monitoring is triggered for digital frequency input X9
• Track monitoring is triggered if a signal cable (A, B, or Z) is interrupted.
Selection list
(Lenze setting in bold)
1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response
;
Read access ; Write access CINH PLC-STOP No transfer
Parameter | Name:
C14041 | Resp. to DFIN enable sig. miss.
Data type: UNSIGNED_8
Index: 10534
d
= 2926
h
Digital frequency extension module in module receptacle MXI2:
Response when "Enable" signal at digital frequency input X9 fails
Selection list
(Lenze setting in bold)
1 Fault
2 Trouble
3 Quick stop by trouble
5 Warning
4 Warning locked
6 Information
0 No response
;
Read access ; Write access CINH PLC-STOP No transfer