4 system block "ls_digitalfrequencyoutput – Lenze E94AYFLF Digital frequency module User Manual
Page 29
EDS94AYFLF EN 3.2 - 10/2010
L
29
Digital frequency extension module | Parameter setting & configuration
Digital frequency output
System block "LS_DigitalFrequencyOutput"
3.4
System block "LS_DigitalFrequencyOutput"
The system block LS_DigitalFrequencyOutput displays the digital frequency output of the
optional extension module in the FB editor of the »Engineer«:
Inputs
Input
Data type
Info/possible settings
DFOUT_dnSpeedSet_s
DINT
Speed in [rpm], which is to be output via the digital frequency output as encoder
signals with TTL level.
• To select this signal source,
= "7" must be set.
Signal source selection ( 23)
DFOUT_bLoadReferencePos
BOOL
Position setting
FALSEÊTRUE Sets the 32-bit absolute position output at the output
DFOUT_dnActualPos_p to the value which is applied to input
DFOUT_dnReferencePos_p.
DFOUT_dnReferencePos_p
DINT
Absolute position in [increments], to which the output DFOUT_dnActualPos_p is set
by a FALSE-TRUE edge at input DFOUT_bLoadReferencePos.
DFOUT_AxisData
V3.0 or higher
Machine parameters
• To transfer the machine parameters of the drive/motor, connect this input to the
output DI_AxisData of SB LS_DriveInterface.
• The machine parameters of a higher-level drive can be transferred via the
FB L_SdSetAxisData. For this purpose, you have to connect the FB's AxisData
output to this input.
• If the input remains unused, the system block continues to operate as before. In
this case the units are scaled to revolutions.
Use of machine parameters for scaling ( 26)
/6B'LJLWDO)UHTXHQF\2XWSXW
')287BGQ5HIHUHQFH3RVBS
'
BE/RDG5HIHUHQFH3RV
)287
'
BGQ$FWXDO3RVBS
)287
'
BGQ$FWXDO6SHHGBV
)287
'
BE2XWSXW)UHT/LPLWHG
)287
;
')287BGQ6SHHG6HWBV
')287B$[LV'DWD