2 parameter setting – Lenze E94AYFLF Digital frequency module User Manual
Page 10
Digital frequency extension module | Parameter setting & configuration
Digital frequency input
Parameter setting
10
L
EDS94AYFLF EN 3.2 - 10/2010
2.2
Parameter setting
Short overview of the parameters for the digital frequency input:
Note!
Depending on the module receptacle the digital frequency extension module is
plugged in, different code ranges are assigned to the parameters!
• Module receptacle MXI1: Parameters are in the C130xx range
• Module receptacle MXI2: Parameters are in the C140xx range
Parameter
Info
Lenze setting
Value Unit
Encoder type DFIN
Digital frequency output DFOUT
No. of increments DFIN
2048
Signal form DFIN
4x evaluation (A, B)
Initialisation time DFIN
3000 ms
Track monitoring DFIN
Active after initialisation time
TP delay time DFIN
0 μs
Speed at DFIN
- Incr./ms
Frequency at DFIN
- Hz
Position at DFIN
- Increments
Resp. to track monitoring DFIN
Warning
No resp. to DFIN enable signal
Warning
Resp. to Vcc error DFIN
Warning
Digital frequency extension module in module receptacle MXI1
Digital frequency extension module in module receptacle MXI2
Greyed out = display parameter