2 table of attributes, Table of attributes, Parameter reference table of attributes – Lenze E94AYFLF Digital frequency module User Manual
Page 45
EDS94AYFLF EN 3.2 - 10/2010
L
45
Digital frequency extension module | Parameter setting & configuration
Parameter reference
Table of attributes
4.2
Table of attributes
The table of attributes contains information required for communicating with the
controller via parameters.
How to read the table of attributes:
Column
Meaning
Entry
Code
Parameter designation
Cxxxxx
Name
Short parameter text (display text)
Text
Index
dec
Index under which the parameter is addressed.
The subindex of array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number
Only required for access via bus
system.
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of array elements (subcodes)
Number
DT
Data type
BITFIELD_8
1 byte bit-coded
BITFIELD_16
2 bytes bit-coded
BITFIELD_32
4 bytes bit-coded
INTEGER_8
1 byte with sign
INTEGER_16
2 bytes with sign
INTEGER_32
4 bytes with sign
UNSIGNED_8
1 byte without sign
UNSIGNED_16
2 bytes without sign
UNSIGNED_32
4 bytes without sign
VISIBLE_STRING
ASCII string
Factor
Factor for data transmission via bus system,
depending on the number of decimal positions.
Factor
1 ≡ no decimal positions
10 ≡ 1 decimal position
100 ≡ 2 decimal positions
1000 ≡ 3 decimal positions
Access
R
Read access
;
Reading allowed
W
Write access
;
Writing allowed
CINH
Controller inhibit required
;
Writing only possible when controller is inhibited