Dimensioning – Lenze EMB9352−C User Manual
Page 78

Dimensioning
Calculate max. running time for brake chopper and brake resistor
l
78
EDBMB935X DE/EN/FR 13.0
I
rated
Rated current EMB9352, mean arithmetic value
t
on
Running time
0
Max. running time for brake resistance B,lim Condition: t on + t off = 3 s 1 Max. running time for brake resistance ³R B,lim Depending on the technical data of the brake resistor Brake resistance R B ³ R B,lim : Calculate running time and dead time t on,max + Q B @ R B U max 2 t off + Q B P N * t on,max t on,max Maximum running time in s t off Dead time in s RB Brake resistance in W U max Max. operating voltage in V P rated Rated power in W Q B Heat in Ws The data can be obtained from the documentation for the brake resistor Brake resistance R B < R B,lim : Condition for the running time and dead time t on,max ) t off + 3 s t on,max Maximum running time in s t off Dead time in s