Technical data, General data and operating conditions, 4technical data – Lenze EMB9352−C User Manual
Page 74

Technical data
General data and operating conditions
4
l
74
EDBMB935X DE/EN/FR 13.0
4
Technical data
4.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
2006/95/EC
Low−Voltage Directive
Approval
UL
cULus
Power Conversion Equipment (File No. E132659)
Protection of persons and equipment
Enclosure
EN 60529
IP10
IP20 with mounted terminal covers
IP41 on the heatsink side for thermally separated
mounting (push−through technique).
NEMA 250
Protection against contact according to type 1
Insulation resistance
IEC/EN 61800−5−1 < 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II
Short−circuit strength
Not short−circuit−proof
Operating conditions
Ambient conditions
Climatic
Storage
IEC/EN 60721−3−1
1K3 (−25 ... +70 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 ... +60 °C)
Operation
IEC/EN 60721−3−3
3K3 (0 ... +40 °C)
without power reduction
3K3 (+40 ... +50 °C)
with power reduction by
2.5%/ °C
Pollution
EN 61800−5−1
Degree of pollution 2
Site altitude h
h
£ 1000 m amsl
without power reduction
1000 m amsl < h <
4000 m amsl
with power reduction by
5 %/ 1000 m
Mechanical
Vibration resistance
EN 50178
EN 61800−5−1
Germanischer
Lloyd, general
conditions
Tested according to "General Vibration Stress
Characteristic 1"