Setting the switching threshold, Electrical installation, Danger – Lenze EMB9352−C User Manual
Page 104

Electrical installation
Setting the switching threshold
l
104
EDBMB935X DE/EN/FR 13.0
7.6
Setting the switching threshold
{
Danger!
ƒ
S1, S2 and S3 have a mains potential!
– Wait for at least 3 minutes before changing over the switches.
Important notes
The switching threshold of the braking unit is the voltage value in the DC bus,
at which the brake resistor is connected.
ƒ
The switching threshold depends on the mains voltage.
–
With the switches S1 and S2 you can adapt the switching threshold to
the corresponding mains voltage of the controller.
ƒ
For all braking units connected in parallel in the DC−bus connection the
same switching threshold has to be set.
Setting
1. Switch the controller to a deenergised state and wait for 3 minutes until
the capacitors of the voltage DC−bus are discharged.
2. Remove terminal cover of the control terminals (at the bottom) from the
braking unit.
3. Set switches S1 and S2 according to the following table:
Mains voltage U
Switching threshold
U
ch
Switch position
[V
eff
]
[V]
S1
S2
230
375
OFF
OFF
400 ... 460
725
ON
OFF
480
765
ON
ON
Bold print: Lenze setting