ASSEMBLY INSTRUCTIONS

3-19

Hydraulic Installation

NOTES

Refer to Figure 3-9 for hydraulic lift diagram.

Refer to Figures 3-10 and 3-11 for hydraulic fold
diagrams.

1.

Install a 16 port manifold to the front side of the
manifold mount bracket at the center frame using
1/2-13 x 3-1/2 hex head cap screws and hex lock
nuts.

2.

Install a 16 port manifold on the front side of the rear
inner tower plate using1/2-13 x 3-1/2 hex head cap
screws and hex lock nuts.

3.

Install the 8 port manifold to the front side of the
manifold mount bracket near the front of the unit
using 1/2-13 x 3-1/2 hex head cap screws and hex
lock nuts.

4.

Install fittings into manifold according to Figures 3-9
and 3-10.

NOTE

Install 90 elbow w/ 1/16 restrictor to both front and rear
top ports of the 16 port manifold near the center of the
frame.

5.

Install wheel lift hoses per Figure 3-9.

6.

Install hydraulic fold hoses per Figure 3-10.

7.

Hold each system of hoses in place using 3/8-16 x 4
hex head cap screw, hose clamps, and hex lock nut
(See Figure 3-12.)

8.

Install steel plugs in any remaining open manifold or
valve ports.

NOTE

Steel plugs will be used in the lower eight ports of each
16 port manifold for all units with either no finishing
attachment or harrow only option included.

9.

Install hose wraps around system hoses per hose
identification decal near hose couplers, putting both
hoses inside wrap (See Figure 3-12.)