Landoll PFT Floating Ring Pulverizer User Manual
Page 17

298rev401
5K089
Page 15
WARNING LIGHTS
Mount the safety warning lights as shown.
1. Attach lamp assemblies to 5K092 brackets (amber facing forward; red and amber facing rear
ward with amber above red). See illustration for fastener requirements.
2. Connect wishbone wiring harness ends to connectors on lamp assemblies. (IMPORTANT:
wires are color coded on wishbone harness. Connect end with yellow wire to left side
lamp assembly. Connect end with green wire to right side lamp assembly). Run wish
bone harness wires along main frame tube to center of machine.
3. Connect straight section wiring harness to center connector of wishbone harness at center of
machine. Run straight section harness along drawbar tube and over to hitch point. All wires
must be firmly attached to machine frame members, or hydraulic lines, so they dont droop or
become torn loose by field debris. Use plastic cable ties, provided, and electrical tape to secure
all wiring.
4. Check to be sure that wiring at center of machine is slack enough so as not to be stretched or
interfered with while rotating frame from transport to field working position and vice versa.
SMV SIGN
Attach the slow moving vehicle bracket as close to rear center as possible.
FIGURE 13
(
Amber only
facing front)
(Amber & Red
toward rear with
Amber above Red)
U-BOLT
5/8 THRD x 7 LONG
LOCK NUT
5/-11
5K092
BRACKET