8 Technical data

2014-06-12

34

8.7

Electrical safety

8.8

Environmental influences

Clearances / creep paths

Mains to electronic components and probe

6 mm

/ ≥

8 mm

Mains to the relay

6 mm

/ ≥

8 mm

Relay to electronic components and probe

6 mm

/ ≥

8 mm

Electrical safety

according to DIN EN 14597 (DIN EN 60730-2-9)
Overvoltage category III, pollution degree 2

Protection type I

with internal separation to SELV current circuits

Ambient temperature range

0 to +55°C

Storage temperature range

-30 to +70°C

Temperature error

± 0.005% / K dev. from 23°C

1

for resistance thermometers

± 0.01% / K dev. from 23°C

1

for thermocouple, current, voltage

Climatic conditions

85% rel. humidity, no condensation
(3K3 with extended temperature range to EN 60721)

EMC

to EN 14597 and standards from the EN 61326 series of standards

Interference emission

Class B

Interference immunity

Test level for safety, control and regulating instruments (RS) to EN 14597

1.All details refer to the full scale value