Chapter 2 operation – INFICON SQC-222 Thin Film Deposition Controller User Manual
Page 25
Chapter 2
Operation
2-6
To delete a layer, highlight it in the Layer Select menu and press Cut/Paste.
On the Cut/Paste menu, press Cut to remove the layer. Press Prev Menu to return to
the Layer Select menu.
C u t / P a s t e M e n u
T o
M a i n
P r e v
M e n u
P r o c e s s 2 5 - > L a y e r 1 - > F ilm 1
L a y e r
F ilm 1
F ilm
L a y e r 1
C o p y
C u t
L a y e r 2
F ilm 2
L a y e r 3
F ilm 3
L a y e r 4
F ilm 4
To move or duplicate a layer, highlight it in the Layer Select menu and press Cut/Paste.
On the Cut/Paste menu, press Cut to remove the layer. A copy of the layer is
automatically saved to copy/paste memory. Press Copy to save a copy to memory
without removing the layer. Without leaving the Cut/Past menu, highlight the layer that
you want to insert the cut layer above and press Paste Normal or Paste CoDep.
Operations on the Cut/Past menu can be repeated several times. Each cut operation
overwrites the cut/paste memory. Pressing Prev Menu on the Cut/Past menu returns to
the Layer Select menu. The contents of copy/paste memory are lost!
Note: Once a film is assigned to a process layer, you cannot change the film. Instead,
cut the layer, then insert a new layer and select the desired film.
- TGF10 Tracer Gas Filler (36 pages)
- Sensistor ILS500 F Leak Detection Filler (90 pages)
- T-Guard Leak Detection Sensor (85 pages)
- T-Guard Leak Detection Sensor Interface description (40 pages)
- Sensistor ISH2000P Hydrogen Leak Detector, Panel Model (51 pages)
- Sensistor ISH2000 HySpeed Hydrogen Leak Detector (54 pages)
- LDS3000 Modular Leak Detector (52 pages)
- LDS3000 Modular Leak Detector Interface description (56 pages)
- BM1000 Bus module (14 pages)
- I/O1000 I/O module (18 pages)
- CU1000 Control unit (24 pages)
- Helium Leak Detector Modul1000 (130 pages)
- Helium Leak Detector Modul1000 Interface description (40 pages)
- UL5000 Dry Helium Leak Detector (108 pages)
- UL5000 Dry Helium Leak Detector Interface description (14 pages)
- UL1000 Fab Dry Helium Leak Detector (119 pages)
- HLD6000 Refrigerant Leak Detector (76 pages)
- HLD6000 Refrigerant Leak Detector Interface Description (40 pages)
- IO1000 I/O module (18 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector (92 pages)
- Ecotec E3000 Multigas-Sniffer-Leak Detector Interface description (36 pages)
- Sensistor XRS9012 Hydrogen Leak Detector User Manual (28 pages)
- Sensistor XRS9012 Hydrogen Leak Detector Maintenance manual (14 pages)
- Extrima Ex-certified Hydrogen Leak Detector (62 pages)
- Sensistor ILS500 Leak Detection System (107 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (108 pages)
- Sensistor ISH2000 Hydrogen Leak Detector (58 pages)
- Sensistor Sentrac Hydrogen Leak Detector (86 pages)
- Protec P3000(XL) Helium Leak Detector (132 pages)
- Pilot Plus Vacuum Gauge (2 pages)
- CO Check Carbon Monoxide Meter (2 pages)
- GAS-Mate Combustible Gas Leak Detector (12 pages)
- Whisper Ultrasonic Leak Detector (8 pages)
- Vortex AC Refrigerant Recovery Machine 115V (20 pages)
- Vortex AC Refrigerant Recovery Machine 230V (16 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (2 pages)
- Wey-TEK Refrigerant Charging Scale & Optional Charging Module (44 pages)
- D-TEK CO2 Refrigerant Leak Detector (12 pages)
- TEK-Mate Refrigerant Leak Detector (12 pages)
- Compass Refrigerant Leak Detector (12 pages)
- D-TEK Select Refrigerant Leak Detector (12 pages)
- Explorer Portable Gas Chromatograph (369 pages)
- MicroFID II Portable Flame Ionization Detector (89 pages)
- DataFID Portable Flame Ionization Detector for Landfill Emissions Monitoring (91 pages)
- Hydrostik Hydrogen Fuel Cylinder Installation (7 pages)