beautypg.com

Frc flux remover c aerosol – HMC Electronics MCC-FRC MicroCare Flux Remover C User Manual

Page 4

background image

6

/

4

VERSION No. 3

FRC FLUX REMOVER C AEROSOL

MATERIALS TO AVOID
Alkali metals. Alkali earth metals. Powdered metal.
HAZARDOUS DECOMPOSITION PRODUCTS
When heated, toxic and corrosive vapors/gases may be formed. Halogenated hydrocarbons. Hydrogen fluoride (HF). Carbon dioxide
(CO2). Carbon monoxide (CO).

11 TOXICOLOGICAL INFORMATION

METHANOL (CAS: 67-56-1)

TOXIC DOSE 1 - LD 50

13000 mg/kg (oral rat)
trans-DICHLOROETHYLENE (CAS: 156-60-5)

TOXIC DOSE 1 - LD 50

1235 mg/kg (oral rat)

TOXIC DOSE 2 - LD 50

>5000 mg/kg (oral-rbt)

TOXIC CONC. - LC 50

24100 ppm/4h (inh-rat)
HFC-134a Tetrafluoroethane (CAS: 811-97-2)

TOXIC DOSE 1 - LD 50

>2085 mg/kg (oral rat)
PENTAFLUOROBUTANE (CAS: 406-58-6)

TOXIC DOSE 1 - LD 50

>2000 mg/kg (oral rat)

TOXIC CONC. - LC 50

25000 ppm/4h (inh-rat)

12 ECOLOGICAL INFORMATION

ECOTOXICITY
There are no data on the ecotoxicity of this product.
MOBILITY
The product contains volatile organic compounds (VOC) which will evaporate easily from all surfaces.
BIOACCUMULATION
No data available on bioaccumulation.
DEGRADABILITY
There are no data on the degradability of this product.
ACUTE FISH TOXICITY
No data available.

trans-DICHLOROETHYLENE (CAS: 156-60-5)

ECOTOXICITY
Low acute toxicity to aquatic organisms.
LC 50, 96 hrs, Fish mg/l

1350

EC 50, 48 hrs, Daphnia, mg/l

220

MOBILITY
The product has poor water-solubility.
BIOACCUMULATION
Bioaccumulation is unlikely to be significant because of the low water solubility of this product.
DEGRADABILITY
No data available.

HFC-134a Tetrafluoroethane (CAS: 811-97-2)

LC 50, 96 hrs, Fish mg/l

450

EC 50, 48 hrs, Daphnia, mg/l

980
PENTAFLUOROBUTANE (CAS: 406-58-6)

LC 50, 96 hrs, Fish mg/l

>200

EC 50, 48 hrs, Daphnia, mg/l

>200

IC 50, 72 hrs, Algae, mg/l

113

MOBILITY
The product has poor water-solubility.
BIOACCUMULATION
Bioaccumulation is unlikely to be significant because of the low water solubility of this product.
DEGRADABILITY
There are no data on the degradability of this product.

Documentation Provided By HMC Electronics

33 Springdale Ave. Canton, MA 02021

http://www.hmcelectronics.com

(800) 482-4440