4.10. User I/Os
The Gold Bell has six programmable digital inputs (J1), four digital outputs (J1) and one analog
input (J2).
4.10.1. Digital Inputs (J1)
Each of the pins below can function as an independent input. The inputs conform to the TTL
level.
Pin (J1) Signal
Function
3
INRET1-6 Programmable inputs 1 - 6 return
4
IN1
Programmable digital input 1
(event capture, home, general purpose, RLS, FLS, INH, PWM & dir
input, pulse & dir input)
5
IN2
Programmable digital input 2
(event capture, home, general purpose, RLS, FLS, INH, PWM & dir
input, pulse & dir input)
6
IN3
Programmable digital input 3
(event capture, home, general purpose, RLS, FLS, INH, PWM & dir
input, pulse & dir input)
7
IN4
Programmable digital input 4
(event capture, home, general purpose, RLS, FLS, INH, PWM & dir
input, pulse & dir input)
8
IN5
Programmable digital input 5
(event capture, home, general purpose, RLS, FLS, INH, PWM & dir
input, pulse & dir input)
9
IN6
Programmable digital input 6
(event capture, home, general purpose, RLS, FLS, INH, PWM & dir
input, pulse & dir input)
Table 17: Digital Input Pin Assignments
See Figure 23 for the TTL connection.