beautypg.com

Auxiliary power supply (optional) – ElmoMC Gold Line Digital Servo Drives-Gold Bell User Manual

Page 40

background image

Gold Bell Installation Guide

Installation

MAN-G-BELIG (Ver. 1.004)

www.elmomc.com

40

4.7.3.

Auxiliary Power Supply (Optional)

Note:

The source of the Auxiliary Supply must be isolated.

Connect the VL+ and PR pins on the Gold Bell in the manner described in Section 4.3.2.1.

Pin

Function

Pin Positions

VL+

Auxiliary Supply Input

PR

Auxiliary Supply Return

Table 11: Auxiliary Supply Pins

Caution:
Power from the Gold Bell to the motor must come from the Main Supply and
not from the Auxiliary Supply.