Port a (j2) – ElmoMC Gold Line Digital Servo Drives-Gold Bell User Manual
Page 47

Gold Bell Installation Guide
Installation
MAN-G-BELIG (Ver. 1.004)
47
4.9.1.
Port A (J2)
Port A supports the following sensor inputs:
•
Digital Hall sensors
•
Incremental encoder or absolute serial encoder, depending on the specific model
Differential pulse-width modulation (PWM) signal input can be connected to port A in the
models that support input from an incremental encoder. The PWM signal can be connected to
the applicable pair of matching + and – encoder channels and is configurable by software.
Differential pulse and direction signal inputs can be connected to port A in the models that
support input from an incremental encoder. The signals can be connected to the applicable pair
of matching + and – encoder channels and are configurable by software.
Port A - Incremental Encoder
Port A - Absolute Serial Encoder
Pin (J2) Signal
Function
Signal
Function
47
+5V
Encoder +5V
supply
+5V
Encoder +5V supply
25
SUPRET
Supply return
SUPRET
Supply return
1
PortA_ENC_A+
Channel A+
ABS_CLK+
Abs encoder clock
+
3
PortA_ENC_A-
Channel A-
ABS_CLK-
Abs encoder clock -
5
PortA_ENC_B+
Channel B+
ABS_DATA+
Abs encoder data +
7
PortA_ENC_B-
Channel B-
ABS_DATA-
Abs encoder data -
9
PortA_ENC_Index+ Index+
Reserved
Reserved
11
PortA_ENC_Index-
Index-
Reserved
Reserved
14
HC
Hall sensor C
HC
Hall sensor C
16
HB
Hall sensor B
HB
Hall sensor B
18
HA
Hall sensor A
HA
Hall sensor A
Table 14: Port A Pin Assignments