2 operation – Eberspacher EasyStart Call User Manual
Page 22

22 | VehiCLe heATeRs – TeChniCAL DOCuMenTATiOn
2 OpeRATiOn
function
sMs command ( = symbol for space)
note /
input options
heater feedback
Entry example 3 on timer programming
pin:1234t
3
:on,time:
We05:50
entry:
pin:1234
for password and space
t3:
for timer 3
on,
to activate heater
(operating mode heat)
time:We.05.50 Departure time Wednesday,
5:50 a.m.
The previous entries for duration (run) and tem-
perature (sp) remain valid.
e.g.
T3:on,time:We.05.50,mode:heater,
run:45,sp:24 (for air heaters only)
activate timer
pin:1234t*:on
* entry
1 2 3
for timer 1, 2 or 3
Activation can only be carried out for the
selected timer.
For note on the heater error message erR,
The “heater error Message” function must be
activated; see installation instructions.
T e.g.2:on,time:FR.16.30,mode:fan,run:40,
sp:24 (for air heaters only)
heater error message, e.g.
– time not valid
erR:DeviceTime:time_not_set,
T2:off
Deactivate timer
pin:1234t*:off
* entry
1 2 3
for timer 1, 2 or 3
Deactivation can only be carried out for the
selected timer.
e.g.
T2:off