2 OpeRATiOn

Day of the week entry
Days of the week can be programmed indi-
vidually or as a day range. you can select from
the following day ranges: MO-FR / sA-su /
MO-su

if a timer is activated with a programmed day
range, all days of the week are always pro-
cessed in succession.

example:
if, during the programmed day range MO - FR,
the timer is activated on Wednesday outside
the programmed time, the heater heats or
ventilates on Thursday and Friday with the
specified settings.

The heater is not operated on saturday and
sunday. From Monday of the following week,
operation continues with the set specifications
for the programmed day range.

cautioN!

if you program a weekday range make sure
that during this time period the vehicle is
not parked in an area where heating is not
allowed, e.g., in a garage or at a petrol sta-
tion.

note and follow the additional safety notes in
the Technical Description of the heater.

nOTes On TiMeR ACTiVATiOn

if the timer is activated, the heater is switched
on under the following conditions:
in departure time mode (factory setting):

ƒ

Current day and pre-selection day are
identical

ƒ

Current time is within the time span
(time span = departure time minus
duration)

When the departure time is reached, the
heater is switched off.

example:
Current day / pre-selection day: Th
Current time: 6.45 pM
Departure time: 7.00 pM
Duration: 30 Minutes
Time span: 6.30 pM to 7.00 pM
The current time is within the time span; the
heater is switched on and heats for 15 min.
(6.45 pM to 7.00 pM).
in start time mode:

ƒ

Current day and pre-selection day are
identical

ƒ

Current time is within the time span
(time span = start time plus 5 minutes)

example:
Current day / pre-selection day: MO
Current time: 3.03 pM
start time: 3.00 pM
Duration: e.g., 30 minutes
Time span: 3.00 pM to 3.05 pM
The current time is within the time span;
the heater is switched on; duration, e.g., 30
minutes.