Notes on timer programming, 2 operation – Eberspacher EasyStart Call User Manual
Page 18

18 | VehiCLe heATeRs – TeChniCAL DOCuMenTATiOn
function
sMs command ( = symbol for space)
note /
input options
heater feedback
heating / ventilating off
pin:1234heater:off
heater:off
heater status readout
pin:1234heater?
For notes on “heater error messages” erD, erh
and erC,
The “heater error Message” function must be
activated; see installation instructions.
e.g.
heater:on or off
,
mode:heater or fan,
run:45,sp:24 (for air heaters only)
possible heater error messages:
– no communication
erD:heaterCom:lost,heater:off
– heater error
erh:heatererror
– error with easystart Call e.g.
erC:Temp:missing
nOTes On TiMeR pROgRAMMing
When programming a timer, you must note the
operating modes of the easystart Call and, if
applicable, the day range.
Departure time mode (factory setting):
in departure time mode (end), if the timer is
activated, the heater is switched off when the
set time is reached.
start time mode:
in start time mode (start), if the timer is acti-
vated, the heater is switched on when the set
time is reached.
2 OpeRATiOn