2 operation – Eberspacher EasyStart Call User Manual
Page 17

Vehicle heaters – Technical Documentation | 17
2 OpeRATiOn
function
sMs command ( = symbol for space)
note /
input options
heater feedback
Ventilating oN
pin:1234heater:on,mode:fan
The last entry for duration (run) remains valid.
e.g.
heater:on,mode:fan,run:45,
heater oN –
with entries for duration and temperature
pin:1234heater:on,run:*,sp:**
*
entry of duration
you can enter a value between
10
and
120
minutes or
perm
for continuous operation.
Continuous operation is only possible for air
heaters.
** entry of temperature value (only for air heat-
ers) Temperature range
8
°C –
36
°C /
46
°F
–
97
°F.
enter single-digit temperature values,
e.g., 9 = correct, 09 = incorrect.
enter double-digit temperature values,
e.g., 21 = correct, 021 = incorrect.
e.g.
heater:on,mode:heater,run:45,
sp:24 (for air heaters only)
Example
entry for heating, continuous operation and tem-
perature for an air heater:
pin:1234heater:on,run:
perm
,sp:
24
entry for heating and duration for a water heater:
pin:1234heater:on,run:
30
heater:on,mode:heater,run:perm,sp:24
heater:on,mode:heater,run:30