beautypg.com

2 operation – Eberspacher EasyStart Call User Manual

Page 21

background image

Vehicle heaters – Technical Documentation | 21

2 OpeRATiOn

function
sMs command (  = symbol for space)

note /

input options

heater feedback

Entry example 1 on timer programming
pin:1234t

1

:on, time:

Tu.06.30

entry:
pin:1234

for password and space

t1:

for timer 1

on,

to activate heater

(operating mode heat)

time:Tu.06.30 Departure time Tuesday, 6:30 a.m.

The previous entries for duration (run) and tem-
perature (sp) remain valid.

e.g.

T1:on,time:Tu.06.30,mode:heater,
run:45,sp:24 (for air heaters only)

Entry example 2 on timer programming
pin:1234t

2

:on,time:

MO-FR.16.30

,mode:

fan

,

run:

40

entry:
pin:1234

for password and space

t2:

for timer 2

on,

to activate heater

time:MO-FR.16.30

start time Monday-Friday,

16:30 p.m.

mode:fan

for operating mode ventilation

run:40

for ventilating duration

40 minutes

The start time for the heater is factory set to
departure time (end). The

start time (start)

must be configured; see installation instruc-
tions.

e.g.

T2:on,time:MO-FR.16.30,mode:fan,
run:40