Overview of the functions, 2 operation – Eberspacher EasyStart Call User Manual
Page 16
16 | VehiCLe heATeRs – TeChniCAL DOCuMenTATiOn
OVeRVieW OF The FunCTiOns
function
sMs command ( = symbol for space)
note /
input options
heater feedback
change password (four digit access PiN)
pin:1234config:set,pin:*
* entry of new 4-digit access pin, permitted
range of
0000
–
9999
.
e.g.
pin:9876
Display current phone number
pin:1234mainphone?
Mainphone:ok,number:current phone
number
authorise the phone number for operating the
Easystart call
pin:1234mainphone:set,number:*
* entry of the current phone number is accepted
with the + symbol or 00 in the country code
(e.g., germany +49 or 0049).
enter max.
24 characters
for a phone number.
Mainphone:ok,number:authorised phone
number
accept phone number of sms sender as
authorised phone number
pin:1234mainphone:set,number:mine
The current phone number is displayed with
the + symbol or 00 in the country code
(e.g., germany +49 or 0049).
Mainphone:ok,number:authorised phone
number
heating oN
pin:1234heater:on
The previous entries for duration (run) and tem-
perature (sp) remain valid.
e.g.
heater:on,mode:heater,run:45,
sp:24 (for air heaters only)
2 OpeRATiOn