beautypg.com

Dakota Ultrasonics DFX-7 plus MANUAL1 User Manual

Page 16

background image

Dakota Ultrasonics

12

3.7 GT2 – Menu

ALARM 2: Toggles the alarm function of gate 2; on, off, audible. The audible
feature sounds a beeper when the waveform breaks the threshold level, either above
or below, depending on the current DETECT setting. Refer to page 31 for further
info.

DETECT: Enables the user to set the alarm detection to occur either above or below
the gates threshold level. Refer to page 31 for further info.

GATE 2: Gates allow the user to view a specific inspection/measurement range, or
specific regions of the waveform, while ignoring others. In order to detect on a
waveform echo, and display the amplitude as a percentage of full screen height, the
echo must be inside the boundaries of the gate settings. The GATE2 feature adjusts
where the gate begins, according to the depth/thickness. Refer to page 31 for further
info.

GATE2 WIDTH: This feature allows the user to set the overall width of the gate, in
terms of distance, from the GATE2 setting. Refer to page 31 for further info.

THRESHOLD 2: Enables the user to set the sensitivity level of Gate2 to a calibrated
screen height percentage. The threshold level will act as a starting point for the
alarm trigger, and is directly associated with the DETECT setting outlined above.
Refer to page 31 for further info.

POLARITY 2: The gates can be set to detect on either the positive or negative
polarity, or stroke, of the half or full wave cycle. It should be noted that if the VIEW is
set to positive, and the gate negative, the DFX-7 will not display an amplitude
percentage of full screen height. Refer to page 31 for further info.

3.8 TRIG – Menu

TRIG: This feature toggles trigonometry feature on/off. This feature is used with
angle beam transducers for the inspection of welds, to calculate three
measurements: Beam path distance (

), Surface distance (), and Depth () from

the index point of the transducer. Refer to page 51 for further info.

THICKNESS: Used to set the thickness of the test material. The thickness will be
used to determine which skip/leg the DFX-7 is detecting on. Refer to page 51 for
further info.

ANGLE: Used to set the angle of the transducer, and used in the calculations above.
Refer to page 51 for further info.

This manual is related to the following products: