The Fusion

®

comes with an alarm panel (see Figure 6) that is

designed to activate an audible buzzer and red beacon light on

top of the panel if there is a drop in air pressure, if a high water

alarm condition occurs, or if the blower does not cycle between

recirculation and backwash modes within the preset time. (Note:

Alarm panel can only function as long as there is electrical power

supplied to the panel)
You may from time to time check the proper operation of the

alarm panel by toggling the black switch on the side of the panel

to “test”. The buzzer will sound and the red beacon will light as

long as you hold the switch in the test position. Release the

switch for normal operation.

A dataplate similar to the one in Figure 5 is located on the blower

housing and the alarm panel. There is important information about

the Fusion

®

on the dataplate, such as the part number, model

number, serial number, and hydraulic capacity. Please make a

note of this information for future reference or in case you should

need to contact your Fusion

®

maintenance provider.

The contracting installer must mark the installed model number

on the dataplate, the blower housing and the alarm control panel.

Figure 6

P/N

WARNING!

RED BEACON

SILENCE/TEST

SWITCH

BUZZER

FUSION

DATAPLATE

sk2649

LEAKY FIXTURES

It is very important to monitor all water fixtures in the home for leaks

and drips and repair them immediately. Leaks can cause tremendous

water use and use may hydraulically overload your Fusion

®

system and

reduce its treatment efficiency. Excessive water use may also overload

your soil absorption field and cause failure.

HIGH USE WATER DEVICES

The draining of hot tubs and swimming pools into your Fusion

®

system

could cause hydraulic overloading and may reduce the treatment

efficiency. Please drain these devices to another location. Contact

your local regulatory authorities or authorized Fusion

®

maintenance

provider for more information. The use of large capacity single fill and

drain whirlpool bathtubs may also cause hydraulic overloading of your

Fusion

®

. Please limit the use of these types of tubs.

The Fusion

®

system is designed to continuously operate automatically

with little direct maintenance from the owner. Periodically, a check of the

blower area is recommended to ensure no debris obstructs the ventilation

or intake areas of the blower. Also, periodically test the control panel

as outlined under the alarm panel section. The owner should closely

monitor the types and amounts of substances and products used. Water

use should also be closely monitored to ensure proper operation of the

Fusion

®

system.

Periodically, more extensive maintenance must be performed. Your

authorized Fusion

®

maintenance provider will oversee this service. The

name of the maintenance provider can be recorded on the front of this

document and should also be located on the alarm panel. For more

information see the Operation and Maintenance section of the manual.
The owner should only perform minimal routine maintenance on the Fusion

®

such as clearing debris from around blower housing (leaves, snow, and

grass clippings). The Fusion

®

should also be protected from excessive

weight such as vehicular traffic. Trees and bushes should not be planted

in close proximity to the Fusion

®

. The Fusion

®

should be accessible to

maintenance personnel and the riser lids must never be buried.

ALARM PANEL

DATAPLATE

FLOODING

If flooding of the Fusion

®

occurs and the blower

or the alarm panel is submerged, please disconnect power at the

circuit breaker. DO NOT try to reconnect power to either the blower

or alarm panel once it has been submerged. Immediately contact your

authorized Fusion

®

maintenance provider to inspect the Fusion

®

, the

blower, and the alarm panel. Your maintenance provider will repair or

replace the components as needed.

Figure 5

SYSTEM CARE

sk2933

Figure 7

1

BLOWER

GND LUG

DISNF

ALARM

TB2

L1

N

GND

2 3 4 5 6 7 8

HIGH WATER

ALARM

120 VAC

INCOMING

POWER

*FOR ILLUSTRATION PURPOSES ONLY*

REFER TO SCHEMATIC LOCATED IN

PANEL FOR INSTALLATION

The Fusion

®

system is designed to function even if wastewater does

not enter it for extended periods of time. The power to the blower

must remain on during this time for the system to function properly.

Weekend use will not harm the system as long as the blower is on.

Should seasonal use require a complete shut down of the property,

then it is recommended that the blower be turned off. It is important

to start up the system in advance of actual occupancy to allow for

normal treatment to resume. Please contact your authorized Fusion

®

maintenance provider for further information concerning shut down and

startup of the Fusion

®

. You may also contact your maintenance provider

for the shut down and startup services.