Clarus Environmental WW1 High Water Alarm Bracket User Manual

High water alarm bracket installation instructions

background image

SECTION: C2.00.110

CL0037

0711

Supersedes

NEW

®

®

3649 Cane Run Road . Louisville, KY 40211-1961

877-244-9340 . Fax: 877-414-4316

www.clarusenvironmental.com

High Water Alarm Bracket

INSTALLATION INSTRUCTIONS

NOTICE TO INSTallEr: Instructions must remain with installation.

© Copyright 2011. All rights reserved.

This High Water Alarm Bracket is designed for use with either the WW1 or WW4 effluent filters from Clarus Environmental.

1)

Determine the most appropriate point of attachment on the effluent filter. Refer to the diagram below.

2)

Determine the appropriate location of the mounting screw hole.

3)

Fasten alarm float bracket to filter using supplied stainless steel screw and washer. It is recommended

that a 1/8” pilot hole be drilled to make the screw easier to install.

4)

Determine float switch (sold separately) placement by adjusting float holder and tether length. Ensure that the

float motion is not obstructed by the filter housing.

5)

Attach filter removal handle (optional).

6)

To complete the installation, follow installation and wiring instructions included in the alarm pack or

control panel (sold separately). Recommended alarm pack – Clarus C-Pak, p/n 10-3067.

WW4 DELUXE EFFLUENT FILTER

WW1 EFFLUENT FILTER

INSTALL ALARM FLOAT

BRACKET ON THE BACK

2 CARTRIDGES

ALARM FLOAT

BRACKET

S.S. WASHER AND

MOUNTING SCREW

THREADED PLUG

FLOAT

HOLDER ASSEMBLY

MOUNTING SCREW HOLE

FLOAT SWITCH

(SOLD SEPARATELY)

1/2" SCH 40 PVC

FILTER REMOVAL HANDLE

(OPTIONAL)

S.S. WASHER AND MOUNTING SCREW

MOUNTING SCREW HOLE

FLOAT

HOLDER ASSEMBLY

FLOAT SWITCH

(SOLD SEPARATELY)

ALARM FLOAT BRACKET

THREADED PLUG

sk2861