Pr el im in a ry – Clarus Environmental Fusion Series Treatment Systems 450/600/800 User Manual
Page 11
11
© Copyright 2012. All rights reserved.
PR
EL
IM
IN
A
RY
Reset (factory default settings):
Press Reset.
Clock is set to 0:00 (midnight).
Backwash Time is set to 2:00 AM.
Backwash Frequency is set to 2 per day. Backwash
Duration is set to 5 mins.
To Adjust Clock & Backwash Settings:
1. Press Mode SW. Note the blinking arrow indicating
"hr" under "Clock" at the right of the screen.
2. Press Set SW to select the current hour of the day.
3. Press Mode SW. Note the blinking arrow indicating
"min" under "Clock" at the right of the screen.
4. Press Set SW to select the current minute of the hour.
5. Press Mode SW. Note the blinking arrow indicating
"Time hr" under "AUTO Back Wash" at the left of the
screen.
6. Press Set SW to select the hour that the system will
begin to back wash. (A setting of 2 is standard)
7. Press Mode SW. Note the blinking arrow indicating
"Freq./Day" under "AUTO Back Wash" at the left of
the screen.
8. Press Set SW to select either 1 or 2 back wash cycles
that the system will perform per day. A setting of 2 is
standard.
9. Press Mode SW. Note the blinking arrow indicating
"Duration min" under "AUTO Back Wash" at the left of
the screen.
10. Press Set SW to select either 5 or 10 minute duration
for back wash cycle. A 5-minute cycle is standard.
NOTE: A 24-hour clock is used in place of AM/PM
designations.
Figure 16
BLOWER TIMER SETTING