Reset (factory default settings):

Press Reset.

Clock is set to 0:00 (midnight).

Backwash Time is set to 2:00 AM.

Backwash Frequency is set to 2 per day. Backwash

Duration is set to 5 mins.

To Adjust Clock & Backwash Settings:

1. Press Mode SW. Note the blinking arrow indicating

"hr" under "Clock" at the right of the screen.

2. Press Set SW to select the current hour of the day.
3. Press Mode SW. Note the blinking arrow indicating

"min" under "Clock" at the right of the screen.

4. Press Set SW to select the current minute of the hour.
5. Press Mode SW. Note the blinking arrow indicating

"Time hr" under "AUTO Back Wash" at the left of the

screen.
6. Press Set SW to select the hour that the system will

begin to back wash. (A setting of 2 is standard)

7. Press Mode SW. Note the blinking arrow indicating

"Freq./Day" under "AUTO Back Wash" at the left of

the screen.

8. Press Set SW to select either 1 or 2 back wash cycles

that the system will perform per day. A setting of 2 is

standard.
9. Press Mode SW. Note the blinking arrow indicating

"Duration min" under "AUTO Back Wash" at the left of

the screen.

10. Press Set SW to select either 5 or 10 minute duration

for back wash cycle. A 5-minute cycle is standard.

NOTE: A 24-hour clock is used in place of AM/PM

designations.

Figure 16

BLOWER TIMER SETTING